The Bayer Contour Blood Glucose Meter manual is a crucial resource for users managing diabetes. It provides detailed instructions on setting up and using the meter, ensuring accurate blood glucose readings. The manual covers essential topics such as meter features, testing procedures, and troubleshooting, helping users maintain their health effectively.

Meter Display

Here are the features and symbols on the Bayer Contour blood glucose meter display as outlined in the manual:

  • Top Area: Displays date and time.
  • Center Area: Shows test results or error codes.
  • Pre-meal Marker: Indicates a pre-meal test result.
  • Post-meal Marker: Indicates a post-meal test result.
  • Logbook Entry: Identifies a logbook entry.
  • Alarm Indicator: Shows that an alarm is set.
  • Sound Indicator: Indicates that sound is turned on.

Setting Up the Meter

Sure, here are the steps to set up your Bayer Contour blood glucose meter, including date, time, and sound settings:

  1. Turn on the Meter: Press and hold the power button until the meter turns on.
  2. Enter Setup Mode: Press and hold the “M” button until the setup screen appears.
  3. Set the Date:
    • Use the arrow buttons to adjust the year, then press “M” to confirm.
    • Repeat for the month and day.
  4. Set the Time:
    • Use the arrow buttons to set the hour, then press “M” to confirm.
    • Repeat for the minutes.
  5. Set the Sound:
    • Use the arrow buttons to turn the sound on or off, then press “M” to confirm.
  6. Exit Setup Mode: Press and hold the power button to exit setup mode.

Your meter is now set up and ready to use!

Control Solution Testing

Here are the steps for control solution testing with the Bayer Contour blood glucose meter:

  1. Prepare the Control Solution: Gently rock the control solution bottle to mix it well.
  2. Apply Control Solution: Squeeze a small drop of control solution onto a clean, nonabsorbent surface (like wax paper). Do not apply it directly to the test strip from the bottle.
  3. Insert Test Strip: Insert a test strip into the meter. The meter will turn on automatically.
  4. Apply Solution to Test Strip: Touch the tip of the test strip to the drop of control solution. The solution will be drawn into the strip.
  5. Wait for Result: The meter will display the result. Compare this result to the range printed on the control solution bottle.

This process ensures your meter and test strips are working correctly.

Performing a Blood Glucose Test

Here’s a step-by-step outline for performing a blood glucose test using the Bayer Contour blood glucose meter:

  1. Wash and dry your hands.
  2. Insert a lancet into the lancing device and adjust the puncture depth.
  3. Insert a test strip into the meter and wait for the flashing blood drop symbol.
  4. Puncture your finger with the lancing device.
  5. Touch the tip of the test strip to the blood drop.
  6. Wait for the meter to beep and display the result.
  7. Mark the result as before or after a meal, if applicable.
  8. Remove the test strip and dispose of it properly.

Error Codes and Symbols

Here are the error codes and symbols for the Bayer Contour blood glucose meter:

  1. E1: Temperature error. The meter is too hot or too cold. Move to an area with a temperature between 10°C and 40°C (50°F and 104°F).
  2. E2: Test strip error. The test strip is damaged or not inserted correctly. Insert a new strip properly.
  3. E3: Sample error. The blood sample is too small or there was an error in applying the sample. Apply a sufficient blood sample.
  4. E4: Meter error. There is an issue with the meter. Restart the meter or replace the batteries.
  5. E5: High glucose. The blood glucose level is above the meter’s readable range. Seek medical advice.
  6. E6: Low glucose. The blood glucose level is below the meter’s readable range. Seek medical advice.
  7. E7: Memory error. There is an issue with the meter’s memory. Restart the meter or contact customer support.
  8. Battery Symbol: Low battery. Replace the batteries soon.
  9. Test Strip Symbol: Indicates the meter is ready for a test strip.
  10. Blood Drop Symbol: Indicates the meter is ready for a blood sample.
  11. Control Solution Symbol: Indicates a control solution test is in progress.

These codes and symbols help ensure accurate readings and proper functioning of your meter.

Changing the Batteries

Here are the steps to change the batteries in the Bayer Contour blood glucose meter:

  1. Turn off the meter.
  2. Locate the battery cover on the back of the meter.
  3. Press firmly on the battery cover and slide it in the direction of the arrow.
  4. Remove the old batteries by pressing the top of the battery to raise the bottom.
  5. Insert new batteries with the “+” side up.
  6. Slide the battery cover back into place and close it firmly.

Make sure to replace the batteries within 5 minutes to retain your settings.

Maintenance and Troubleshooting

Here are some tips for maintaining your Bayer Contour blood glucose meter and troubleshooting common issues:

Maintenance Tips

  1. Keep it Clean: Wipe the meter with a damp cloth. Avoid getting moisture in the test strip port.
  2. Store Properly: Keep the meter and test strips in a cool, dry place. Avoid extreme temperatures.
  3. Check Batteries: Replace the batteries when the low battery symbol appears.
  4. Use Original Test Strips: Always use Bayer Contour test strips for accurate results.

Troubleshooting Common Issues

  1. Error Codes: Refer to the user manual for specific error codes and their meanings.
  2. Inconsistent Readings: Ensure hands are clean and dry before testing. Use a new test strip each time.
  3. Meter Won’t Turn On: Check and replace batteries if needed. Ensure test strips are properly inserted.
  4. Blood Sample Issues: Make sure to get a sufficient blood sample. If the sample is too small, the meter may not read correctly.

If problems persist, consult the user manual or contact customer support for further assistance.

The Bayer Contour Blood Glucose Meter Manual

The Bayer Contour Blood Glucose Meter manual is a crucial resource for users managing diabetes, providing detailed instructions on setting up and using the meter to ensure accurate blood glucose readings.

Key points covered in the manual include:

  • Setting up the meter with date, time, and sound settings;
  • Performing control solution testing;
  • Conducting blood glucose tests;
  • Troubleshooting error codes and symbols;
  • Maintaining the meter through cleaning, storage, and battery replacement.

The manual emphasizes the importance of proper use and maintenance to ensure accurate readings and effective diabetes management.